Abstract
Background: Lots of trials demonstrate that second-generation drug-eluting stents (G2-DES), with their improved properties, offer significantly superior efficacy and safety profiles compared to first generation DES (G1-DES) for patients with coronary artery disease (CAD) receiving percutaneous coronary intervention (PCI). This study aimed to verify the advantage of G2-DES over G1-DES in Chinese patients with stable CAD (SCAD).
Methods: For this retrospective observational analysis, 2709 SCAD patients with either G1-DES (n = 863) or G2-DES (n = 1846) were enrolled consecutively throughout 2013. Propensity score matching (PSM) was applied to control differing baseline factors. Two-year outcomes, including major adverse coronary events as well as individual events, including target vessel-related myocardial infarction, target lesion revascularization (TLR), target vessel revascularization, and cardiogenic death were evaluated.
Results: The incidence of revascularization between G1- and G2-DES showed a trend of significant difference with a threshold P - value (8.6% vs. 6.7%, χ2 = 2.995, P = 0.084). G2-DES significantly improved TLR-free survival compared to G1-DES (96.6% vs. 97.9%, P = 0.049) and revascularization-free survival curve showed a trend of improvement of G2-DES (92.0% vs. 93.8%, P = 0.082). These differences diminished after PSM. Multivariate Cox proportional hazard regression analysis showed a trend for G1-associated increase in revascularization (hazard ratio: 1.28, 95% confidence interval: 0.95-1.72, P = 0.099) while no significance was found after PSM. Other endpoints showed no significant differences after multivariate adjustment regardless of PSM.
Conclusions: G1-DES showed the same safety as G2-DES in this large Chinese cohort of real-world patients. However, G2-DES improved TLR-free survival of SCAD patients 2 years after PCI. The advantage was influenced by baseline clinical factors. G1-DES was associated with a trend of increase in revascularization risk and was not an independent predictor of worse medium-term prognosis compared with G2-DES.
Document Type
Article
Publication Date
7-20-2017
Digital Object Identifier (DOI)
https://doi.org/10.4103/0366-6999.209904
Funding Information
This study was supported by grants from the National Natural Science Foundation of China (No. 81470486) and the National Key Research and Development Program of China during the 13th Five‑Year Plan Period (No. 2016YFC1301301).
Repository Citation
Liu, Ru; Xiong, Fei; Wen, Yuan; Ma, Yuan-Liang; Yao, Yi; Gao, Zhan; Xu, Bo; Yang, Yue-Jin; Qiao, Shu-Bin; Gao, Run-Lin; and Yuan, Jin-Qing, "Comparison of Efficacy and Safety Between First and Second Generation Drug-Eluting Stents in Patients with Stable Coronary Artery Disease: A Single-Center Retrospective Study" (2017). Physiology Faculty Publications. 107.
https://uknowledge.uky.edu/physiology_facpub/107
Notes/Citation Information
Published in Chinese Medical Journal, v. 130, issue 14, p. 1654-1661.
© 2017 Chinese Medical Journal
This is an open access article distributed under the terms of the Creative Commons Attribution‑NonCommercial‑ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non‑commercially, as long as the author is credited and the new creations are licensed under the identical terms.