Publication Date

1997

Description

The proanthocyanidin (butanol-HCl) assay was used to measure condensed tannin (CT) in extracts from Leucaena spp. at the University of Queensland. Inconsistent results were found to be caused by the iron catalyst in the butanol/HCl reagent and the presence of ascorbic acid in the sample matrix which enhanced anthocyanidin development. In addition, preparation of sample extracts by back extraction with organic solvents reduced CT recoveries. An accurate and rapid technique was developed that measures CT directly in 70% aqueous acetone 0.1% (w/v) sodium metabisulphite plant extracts.

Share

COinS
 

A Revised Method of Condensed Tannin Analysis in Leucaena spp.

The proanthocyanidin (butanol-HCl) assay was used to measure condensed tannin (CT) in extracts from Leucaena spp. at the University of Queensland. Inconsistent results were found to be caused by the iron catalyst in the butanol/HCl reagent and the presence of ascorbic acid in the sample matrix which enhanced anthocyanidin development. In addition, preparation of sample extracts by back extraction with organic solvents reduced CT recoveries. An accurate and rapid technique was developed that measures CT directly in 70% aqueous acetone 0.1% (w/v) sodium metabisulphite plant extracts.