Abstract
Background
Patients with repaired tetralogy of Fallot (TOF) frequently have right bundle branch block. However, the contribution of cardiac dyssynchrony to dysfunction remains controversial. To better understand this phenomenon and ultimately study therapies, we developed a method to quantify left (LV), right (RV) and inter-ventricular cardiac dyssynchrony using standard cine CMR.
Methods
30 patients with repaired TOF (age 28 ± 16, 46% female) and 17 healthy controls (age 29 ± 7, 12% female) underwent cine CMR. Patients were imaged twice to assess inter-test reproducibility. Circumferential strain vs time curves were generated with a custom feature tracking algorithm for 12 LV and 12 RV segments in 4-7 slices encompassing the ventricles. For each segment, the temporal offset (TO) of the strain curve relative to a global reference curve derived from the controls was calculated and expressed as a percent of the cardiac cycle. The intra-ventricular dyssynchrony index (DI) for each ventricle was computed as the standard deviation (SD) of the TOs (more dyssynchrony increases the SD). The inter-ventricular DI was calculated as the difference in median RV and median LV TOs. Regional dyssynchrony was quantified in 3 LV (septum, infero-lateral and antero-lateral wall) and 3 RV (septum, sinus, outflow tract) regions using median TOs.
Results
Compared to controls, patients with repaired TOF had a greater LV, RV and inter-ventricular DI. The greater inter-ventricular delay in the patients was primarily due to a global delay in RV contraction with the RV contracting 4.9 ± 3.5% later than the LV in patients vs 1.4 ± 3.2% earlier in controls. Median TOs were similar in the three LV regions between patients and controls, but all three RV regions were significantly delayed in patients compared to the controls. Contraction patterns in the RV were also distinct: in controls, the earliest contraction was seen in the outflow tract; in patients, contraction occurred first in the septum and last in the outflow tract. Inter-test reproducibility for the three DIs was good with all coefficients of variation
Conclusions
Patients with repaired TOF suffer from left, right and inter-ventricular cardiac dyssynchrony which can all be quantified from standard cine CMR with good inter-test reproducibility. Future studies need to determine whether these patients may benefit from resynchronization therapy.
Document Type
Presentation
Publication Date
1-16-2014
Digital Object Identifier (DOI)
http://dx.doi.org/10.1186/1532-429X-16-S1-P120
Repository Citation
Jing, Linyuan; Haggerty, Christopher M.; Suever, Jonathan D.; Prakash, Ashwin; Cecchin, Frank; Skrinjar, Oskar; Geva, Tal; Powell, Andrew J.; and Fornwalt, Brandon K., "Assessment of Intra- and Inter-Ventricular Cardiac Dyssynchrony in Patients with Repaired Tetralogy of Fallot: A Cardiac Magnetic Resonance Study" (2014). Pediatrics Presentations. 3.
https://uknowledge.uky.edu/pediatrics_present/3
Notes/Citation Information
Published in Journal of Cardiovascular Magnetic Resonance, v. 16, suppl. 1, p. 1-2.
© 2014 Jing et al.; licensee BioMed Central Ltd.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.